Industrial Engineering Calculators

Weight, pressure rating (ASME B31.3), wall thickness, hydrotest, and bid EMD calculators. Accurate ASTM density values for SS, Duplex, Inconel, Monel, Hastelloy, Titanium, Cu-Ni, and more.

Per Piece
kg
Total Weight
kg
Per Meter
kg/m
⚙️ ASME B31.3 Process Piping — Maximum Allowable Working Pressure (MAWP) using Barlow's modified formula. Always verify with PE-stamped calculations for actual design.
MAWP
bar (gauge)
MAWP
MPa
MAWP
psi
📏 Calculate required minimum wall thickness for given design pressure (ASME B31.3 inverse formula).
Min. Required
mm
With CA (1.5mm)
mm
Suggested Schedule
SCH
💧 Hydrostatic test pressure per ASME B31.3 — Pₕ = 1.5 × P_design × (Sₜ/S_d). Standard practice for pre-commissioning piping.
Hydrotest
bar
Hydrotest
psi
Hold Time
10
min minimum
💰 Earnest Money Deposit per GEM bid rules. Below ₹25 Lakh → EMD waived. ₹25L-₹4Cr → 2-3%. Above ₹4Cr → ePBG required separately.
EMD Amount
As Words
ePBG (5%)
📋 ANSI/ASME B36.10 (CS) and B36.19 (SS) pipe dimensions. Enter NPS to see all schedule thicknesses.

Accurate Density Reference (ASTM Standards)

Industry-standard density values used in our calculations. Each grade verified against current ASTM/ASME specifications.

GradeUNSDensity (g/cm³)kg/m³ASTM Spec
SS 304/304LS30400/S304038.008000A312/A240
SS 316/316LS31600/S316037.997990A312/A240
SS 321S321007.927920A312/A240
SS 310SS310087.867860A312/A240
SS 904LN089048.008000B677
Duplex 2205S318037.807800A790/A240
Super Duplex 2507S327507.797790A790/A240
Inconel 600N066008.478470B167/B168
Inconel 625N066258.448440B444/B443
Inconel 718N077188.198190B637/B670
Inconel 825N088258.148140B423
Monel 400N044008.838830B164/B127
Hastelloy C276N102768.898890B622/B575
Hastelloy C22N060228.698690B622/B575
Titanium Gr.2R504004.514510B861/B265
Titanium Gr.5 (6Al-4V)R564004.434430B861/B265
Alloy P91K909017.787780A335
Cupro-Nickel 70/30C715008.958950B466
Aluminium 6061A960612.702700B221